Myocardial perfusion scan results (primary care)
Name radio_scan_gprd
Chapter Circulatory disease/Stable angina
Definition
Myocardial perfusion scan results, as recorded in primary care (CPRD)
Data Type Categorical
Data sources GPRD
Dictionaries Read
Repeated Yes
Valid event date range 01/01/1900 - 25/03/2010
Agreed 10.04.2014 (Revision 2)
Category Definition
0 Test not done
1 Results normal
2 Results potentially abnormal
3 Results abnormal
4 Results not recorded
5 Code conflict (normal/potentially abnormal)
6 Code conflict (normal/abnormal)
7 Code conflict (potentially abnormal/abnormal)
Implementation
With clinical file, IF Read code = code in radioisotope scan code list, THEN
radio_scan_gprd = relevant category

With test file, IF Read code = code in radioisotope scan code list AND enttype = 251 or 298, THEN
radio_scan_gprd = appropriate category from data1
Codelist version1
Codelist authorsJulie George, Emily Herrett, Liam Smeeth, Harry Hemingway
Creation date14 Apr 2011
Category (code) Read code Read term CPRD Medcode
Results normal (1) 5C02.00 Radionuclide heart study normal 40638
Results potentially abnormal (2) 5C21.00 Radionuclide heart studies equivocal 66179
Results abnormal (3) 5C11.00 Radionuclide heart study abnormal 58135
Results not recorded (4) 573D.00 Isotope static scan heart 28664
Results not recorded (4) 573D.11 Thalium scan of heart 4418
Results not recorded (4) 7L12300 Myocardial perfusion scan 11368
Results not recorded (4) 7P07300 Myocardial positron emission tomography 95769
Results not recorded (4) 7P07400 Radionuclide angiocardiography 86324
Results not recorded (4) 7P07500 Myocardial perfusion scan 39135
Results not recorded (4) 7P07600 Cardiac multiple gated acquisition scan 70706
Results not recorded (4) 7P07711 Exercise tolerance test with myoview scan 98231
Results not recorded (4) 7P08400 Thallium stress test 51479
Results not recorded (4) 7P0J200 Positron emission tomography NEC 67282
Results not recorded (4) 7P0J300 Single photon emission computed tomography NEC 91082
Results not recorded (4) 7P0M100 Positron emission tomography with computed tomography NEC 97108
comments powered by Disqus